EHouse Building Automation - Connecting implementing relay drivers. Mini Distribution - Installation of decentralized dash board @ Home Automation eHouse.Pro
EHouse Home Automation is a system of low - voltage (consumer electronics), supplied with a constant voltage of about 12V. Microprocessor controllers internal stabilized power, allowing the voltage bulb icon drop to the value required for the direct supply of the processor. bulb icon This may be 5V, 3V, 3V3, 3V6, or any other value, depending on the type of controller and the microprocessor.
This is unacceptable for drivers to connect external voltage, that as a result of transient, interference, break, etc. . can lead to damage to the controller or at least reduce stability of the processor due to the sudden and uncontrolled discharge. Electrical connection to the system bulb icon EHouse bulb icon requires separate relays and connecting external high - power devices. This is the simplest, Emergency cheapest way, providing long - term and proper functioning of the system in all conditions. Relay modules can be used for each controller containing a set of relays for all outputs. An alternative to the relay module is the use of individual relays on DIN rail (as standard fuses 230). They can be installed in a distribution center or directly controlled areas (in small control cabinet). The second solution from the viewpoint of installation, and low budget is much better and more economical: Repeatedly reduce bulb icon the consumption of 230 wires to turn electrical devices and their cost (distribution bulb icon only in one room) significantly reduce the power loss in the lines 230 This significantly reduces wiring time (work) Adding the finishing line does not require the destruction of the entire route cables to a central distribution is limited to only one room Any faults or damage do not cover the entire building automation system, but one segment of the service does not require a complete stop of the system, but only serves the segment is much easier to replace a relay in a small box than a large closet for EHouse system selected relays should be used EHouse, which have very low operating current and low noise in transient state. Given the large number of outputs bulb icon in EHouse controllers and the potentially large number of devices are involved, the controller can release large amounts of heat. In extreme cases, this can reduce the life of the driver, especially where they are located in the small events, which prevents the flow of cooling air. It is also useful to check a few relays from each box ,, parameters which may differ bulb icon significantly. Induced glitches when switching the relay may even exceed several times the value of the voltage relay, which can damage the controller output, even when using protective diodes - "clamping". Installation and connection of the relay system is very easy, However, connecting voltage 230V requires extreme care and precision, should be made and checked by a qualified electrician. Use of relays for DIN-rail with stand, bulb icon significantly speed up and facilitate the exchange of the relay in case of damage. Otherwise, replace the relay on a DIN rail packed with connected conductors is very time consuming and difficult. Parts of the relay before assembly bulb icon Example window for installation in a room controlled relays - decentralized system. You can use any electrical box, Concealed available on the market. You can use one or more lines of the box. Supply of space will not hurt, and much easier stacking and flexible rigid pipe 230 and wider. Ultimately, it can be placed behind a small cabinet or planned to not marred bed room. Revision is actually necessary only in case of failure of the relay, So it must be available for the purposes of subsequent service. Setting the distribution of the mini be carried out without the use of flammable liquids (such as polyurethane foam) and conductive materials. In addition, all openings must be protected against possible entry of rodents and insects. Installing one relay in the fuse box rail relay Installation in a box set for the controlled room (with one RoomManager) relay consists of a coil (solenoid) relay contacts switching under the influence of the applied voltage to the coil. Relays may have one or two independent sets of contacts (no connection between them). On the right side of the same set in the second left side. The relay switch operates bulb icon as usual, but not activated bulb icon manually, but automatically by energizing the coil drives, a controller with a built-in logic. Common to all the power coils +12 V (or other, depending on the voltage on the relay) is connected as follows. For energy conservation, UPS or battery,
EHouse Home Automation is a system of low - voltage (consumer electronics), supplied with a constant voltage of about 12V. Microprocessor controllers internal stabilized power, allowing the voltage bulb icon drop to the value required for the direct supply of the processor. bulb icon This may be 5V, 3V, 3V3, 3V6, or any other value, depending on the type of controller and the microprocessor.
This is unacceptable for drivers to connect external voltage, that as a result of transient, interference, break, etc. . can lead to damage to the controller or at least reduce stability of the processor due to the sudden and uncontrolled discharge. Electrical connection to the system bulb icon EHouse bulb icon requires separate relays and connecting external high - power devices. This is the simplest, Emergency cheapest way, providing long - term and proper functioning of the system in all conditions. Relay modules can be used for each controller containing a set of relays for all outputs. An alternative to the relay module is the use of individual relays on DIN rail (as standard fuses 230). They can be installed in a distribution center or directly controlled areas (in small control cabinet). The second solution from the viewpoint of installation, and low budget is much better and more economical: Repeatedly reduce bulb icon the consumption of 230 wires to turn electrical devices and their cost (distribution bulb icon only in one room) significantly reduce the power loss in the lines 230 This significantly reduces wiring time (work) Adding the finishing line does not require the destruction of the entire route cables to a central distribution is limited to only one room Any faults or damage do not cover the entire building automation system, but one segment of the service does not require a complete stop of the system, but only serves the segment is much easier to replace a relay in a small box than a large closet for EHouse system selected relays should be used EHouse, which have very low operating current and low noise in transient state. Given the large number of outputs bulb icon in EHouse controllers and the potentially large number of devices are involved, the controller can release large amounts of heat. In extreme cases, this can reduce the life of the driver, especially where they are located in the small events, which prevents the flow of cooling air. It is also useful to check a few relays from each box ,, parameters which may differ bulb icon significantly. Induced glitches when switching the relay may even exceed several times the value of the voltage relay, which can damage the controller output, even when using protective diodes - "clamping". Installation and connection of the relay system is very easy, However, connecting voltage 230V requires extreme care and precision, should be made and checked by a qualified electrician. Use of relays for DIN-rail with stand, bulb icon significantly speed up and facilitate the exchange of the relay in case of damage. Otherwise, replace the relay on a DIN rail packed with connected conductors is very time consuming and difficult. Parts of the relay before assembly bulb icon Example window for installation in a room controlled relays - decentralized system. You can use any electrical box, Concealed available on the market. You can use one or more lines of the box. Supply of space will not hurt, and much easier stacking and flexible rigid pipe 230 and wider. Ultimately, it can be placed behind a small cabinet or planned to not marred bed room. Revision is actually necessary only in case of failure of the relay, So it must be available for the purposes of subsequent service. Setting the distribution of the mini be carried out without the use of flammable liquids (such as polyurethane foam) and conductive materials. In addition, all openings must be protected against possible entry of rodents and insects. Installing one relay in the fuse box rail relay Installation in a box set for the controlled room (with one RoomManager) relay consists of a coil (solenoid) relay contacts switching under the influence of the applied voltage to the coil. Relays may have one or two independent sets of contacts (no connection between them). On the right side of the same set in the second left side. The relay switch operates bulb icon as usual, but not activated bulb icon manually, but automatically by energizing the coil drives, a controller with a built-in logic. Common to all the power coils +12 V (or other, depending on the voltage on the relay) is connected as follows. For energy conservation, UPS or battery,
No comments:
Post a Comment